Methodology & sources

We implement the arithmetic of each method in our own code and words and cite section numbers. We do not reproduce NFPA 70 text or tables. Read the code itself via NFPA's free access.

What the calculator does

MethodOur implementationStatus
220.83(A) 2020/20233 VA/sq ft, 1,500 VA per small-appliance and laundry circuit, nameplates; first 8 kVA at 100%, remainder 40%Checked against the NEC Mastery worked example (94 A)
220.83(B) 2020/2023When adding heat or A/C: larger of heating or cooling at 100%, the rest tieredSecondary sources (NEC Mastery, Intrysys)
120.83 20262 VA/sq ft; existing first 8 kVA 100%, remainder 40%; new EVSE 80%, new central resistance heat 80%, other new 50%; fill the 8 kVA tier with existing load first, then new loads lowest factor firstAssumption: from multiple secondary summaries, not checked against printed NFPA 70-2026; tier-fill order is our conservative reading
220.82 / 120.82General load first 10 kVA (2026: 8 kVA) at 100%, rest 40%; plus largest of A/C & heat pump at 100%, heat pump + 65% supplemental, or resistance heat at 65%2020/2023 from secondary sources; 2026 changes are an assumption (The Power Estimator summary). Simplified: the 40% rule for four or more separately controlled heating units is not modeled
220.87 / 120.8712-month peak kW × 125% + new loads at full nameplate (conservative)Secondary sources (Intrysys)
220.57 EVSE2023: larger of 7,200 VA or nameplate; 2026: nameplate; 2020: nameplateSecondary sources
Heating vs coolingOnly the larger side counts in every method (non-coincident loads, 220.60)Assumption for 2020/2023 220.83(A), where some AHJs count both
Status"Within rating" ≥10% headroom, "under 10% headroom", or "over rating"Our presentation choice, not a code term

Verified

Not verified (labeled assumptions)

Sources

Estimate only; a licensed electrician and your local authority having jurisdiction decide; not an engineering stamp.